Price: €73.79
Under normal conditions, rain water will the tank. If the rainwater level drops below a pre-set level, the RainAid® valve will open to maintain the water level using mains water.Standards
- Certified to Watermark standard AS1910:2004,Lic 20368, SAI Global
- New Zealand patent. 328862
- New Zealand patent. 535912
- Australian patent. 736446
- RSA Patent. 98/8777
- Australian Class II Patent 1025211
Specifications
| Inlet | 20mm 3/4" BSP (male) |
- Cold mains pressure water connection.
- Minimum inlet pressure 55 kPa (8 P.S.I.).
- Maximum inlet pressure 1000 kPa (150 P.S.I.).
- Maximum water temperature 60˚C.
- Supplied with inlet strainer.
Installation
- The RainAid® valve MUST NOT be fitted to tanks used partially or entirely for storm water detention. (Detention is the slow release of water run-off to the storm water drain during and after rainfall events).
- Do not restrict inlet water flow.
- Not to be modified.
- Valve must be installed horizontally.
- Overflow discharge must be visible.
- Overflow and air gap to comply with local standards (air gap of 3 x mains water inlet pipe diameter - 55mm - complies with AS/NZS 3500.1)
- The minimum water level (L) is easily set at any height during installation by adjusting the cord length.
- Cord must hang freely.
- Failure to affix label, supplied with the valve, near the visible overflow discharge will void Warranty.
For installation Video please see